Biological Indicator Specification

  • Core Components
  • Biological Spore Suspension, Culture Medium, Vial
  • Measurement Range
  • 10 to 10 spores per vial
  • Automation Grade
  • Manual
  • Frequency
  • Single-use
  • Capacity
  • 10 ml per vial
  • Model No
  • BI-STEAM-10ML
  • Accuracy
  • >99% pass/fail detection
  • Feature
  • Rapid color-change, easy interpretation
  • Temperature Range
  • 121C to 134C
  • Equipment Materials
  • Polypropylene vial, glass ampoule
  • Type
  • Steam Biological Indicator
  • Usage
  • Sterilization process monitoring
  • Display Type
  • Visual color change
  • Dimension (L*W*H)
  • 10 mm x 60 mm
  • Weight
  • Approx. 15 g per indicator
  • Detection Principle
  • Biological Spore Growth
  • Sterilization Method
  • Steam
  • Incubation Time
  • 24 hours recommended
  • Indicator Organism
  • Geobacillus stearothermophilus
  • Compliance
  • ISO 11138
  • Shelf Life
  • 18 months
  • Storage Conditions
  • Room temperature, dry place
  • Packaging Type
  • Pack of 50 indicators
 

Biological Indicator Trade Information

  • Minimum Order Quantity
  • 2 Packs
  • Supply Ability
  • 1000 Packs Per Day
  • Delivery Time
  • 4-5 Days
 

About Biological Indicator

Biological Indicator

Being a distinguished organization in this sphere, we manufacture, supply and export Biological Indicator. This product is useful in assessing the presence of pollutants in the ecosystem with the medium of typical measurable responses. Our offered product is efficient in monitoring autoclave efficiency. This Biological Indicator is made up of premium raw components which are obtained at our end from the reliable sources. After the manufacturing, this product is packed using quality plastic bags and cartons, with a desire to provide safe transit at the patrons defined place.

Features:

  • Easy to operate

  • Accurate results

  • Digital quality

  • Compact design



Fast and Accurate Results

BI-STEAM-10ML supports rapid detection with a 24-hour incubation period. The visual color change ensures straightforward interpretation, allowing swift quality assurance within sterilization processes.


Robust Component Design

Manufactured from polypropylene and glass, the indicator vials are durable and easy to handle. The efficient packaging in packs of 50 units meets the needs of high-throughput facilities.


Reliable Compliance & Storage

Complying with ISO 11138 standards, these indicators guarantee consistent performance and safety. Simple storage at room temperature in a dry place extends usability to 18 months.

FAQs of Biological Indicator:


Q: How does the BI-STEAM-10ML Biological Indicator detect sterilization efficacy?

A: The BI-STEAM-10ML uses Geobacillus stearothermophilus spores and a culture medium. After a steam sterilization cycle, if the process is successful, there will be no growth and the medium remains unchanged. If sterilization fails, spore growth triggers a rapid visual color change in the medium, confirming process adequacy.

Q: What is the recommended incubation time for these indicators?

A: A 24-hour incubation period is recommended to obtain reliable results on the effectiveness of the sterilization cycle, thanks to the rapid growth and detection principle of the indicator organism.

Q: When should the BI-STEAM-10ML Biological Indicators be used during sterilization?

A: These indicators are intended for use during each steam sterilization cycle to monitor and validate that the cycle achieved the necessary microbial inactivation, ensuring compliance and safety.

Q: Where should unused biological indicators be stored?

A: Unused indicators should be kept at room temperature in a dry environment to maintain their integrity and effectiveness throughout the 18-month shelf life.

Q: What components make up the BI-STEAM-10ML indicator vial?

A: Each vial includes a biological spore suspension, sterile culture medium, a polypropylene vial, and a glass ampoule, ensuring reliable containment and accurate assessment.

Q: How is the result displayed after incubation?

A: The BI-STEAM-10ML displays results through a visual color change in the culture medium. A color shift indicates spore growth and sterilization failure, while no change signifies a successful cycle, allowing for straightforward pass/fail detection (>99% accuracy).

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Microbiological Products Category

Dyanox Anaerobic Jars

Dyanox Anaerobic Jars

Price 5175 INR / Unit

Minimum Order Quantity : 1 , , Unit

Usage : Microbiological and anaerobic culture applications

Automation Grade : Manual operation

Type : Anaerobic Culture Jar

Temperature Range : Ambient to 60C (when used with external incubator)

Antimicrobial Mega Ring

Antimicrobial Mega Ring

Price 247 INR / Pack

Minimum Order Quantity : 10 Packs

Usage : Wastewater Treatment, Oil Water Separators, Cooling Towers, Biofilm Control

Automation Grade : Manual

Type : Antimicrobial Mega Ring

Temperature Range : Up to 90C

Sterile Empty Petridishes

Sterile Empty Petridishes

Price 45 INR / Unit

Minimum Order Quantity : 50 Units

Usage : Microbiological culture and lab use

Automation Grade : Manual

Type : Sterile Empty Petridishes

Temperature Range : Up to 121C (autoclavable)

Swab Sticks

Swab Sticks

Price 165 INR / Pack

Minimum Order Quantity : 10 Packs

Usage : Medical, Laboratory, Sample Collection, Personal Care

Automation Grade : Manual

Type : Swab Stick

Temperature Range : Ambient to 40C